Main: Neutron generators: Physical research
Vacuum tube based pulsed neutron generator for the physical research applications
Pulsed neutron generator using vacuum tube for physical research
The generator design includes:
- neutron emission unit consisting of tube module and high-voltage power supply module;
- control unit;
- connecting cable.
ING-10 technical characteristics
| Average neutron output per pulse, n, neutron/pulse |
1·107 |
| Neutron pulse width, µsec |
not more than 1,0 |
Neutron pulse repetition rate, f, Hz: - in continuous operating mode - in cyclic operating mode |
up to 20 up to 50 |
| Neutron background between neutron pulses |
NO |
| Produced neutron flux, F=n·f, neutron/sec |
up to 5·108 |
| Tube module average operating life *, pulses |
1·107 |
| Power consumption, W |
not more than 150 |
Dimensions, mm, of: - neutron emission unit - control unit |
Ø 34x1320 420x100x310 |
Weight, kg, of: - neutron emission unit - control unit |
not more than 2,5 not more than 4,7 |
| Connecting cable length, m |
25 |
| Power supply |
220/127 V mains, 50 Hz |
*) tube module is a replaceable part
Pulsed neutron generator using vacuum tube for physical research
The generator design includes:
- neutron emission unit consisting of tube module and high-voltage power supply module;
- control unit;
- connecting cable.
ING-12 technical characteristics
| Average neutron output per pulse, n, neutron/pulse |
3·107 |
| Neutron pulse width, µsec |
not more than 1,0 |
Neutron pulse repetition rate, f, Hz: - in continuous operating mode - in cyclic operating mode |
up to 30 up to 100 |
| Neutron background between neutron pulses |
NO |
| Produced neutron flux, F=n·f, neutron/sec |
up to 2·109 |
| Tube module average operating life *, pulses |
1·107 |
| Power consumption, W |
not more than 200 |
Dimensions, mm, of: - neutron emission unit - control unit |
Ø 49x1000 420x100x310 |
Weight, kg, of: - neutron emission unit - control unit |
not more than 3,5 not more than 4,7 |
| Connecting cable length, m |
25 |
| Power supply |
220/127 V mains, 50 Hz |
*) tube module is a replaceable part
Plasma focus chamber based pulsed neutron generator for physical research applications
The generator design includes:
- current pulse generator with plasma focus chamber;
- control unit;
- set of connecting cables.
ING-102 technical characteristics
| Average D-T neutron output per pulse, neutron/pulse |
5·107 |
| Average D-D neutron output per pulse, neutron/pulse |
5·105 |
| Relative mean quadratic deviation of output from average, % |
10-20 |
| Neutron pulse duration at 0,5 amplitude value, nsec |
10 |
| Chamber operating life (number of turns-on) *, not less than |
1000 |
| Generator operating life (number of turns-on), not less than |
10000 |
| Operating temperature range |
-15 - +50 °C |
| Power supply |
220 V mains, 50 Hz |
| Power consumption, W |
50 |
| Weight, kg |
20 |
| Dimensions, mm |
Ø 250x700 |
*) chamber is a replaceable part
Plasma focus chamber based pulsed neutron generator for physical research applications
The generator design includes:
- current pulse generator with plasma focus chamber;
- control unit;
- up to 50 m long connecting cables.
ING-103 technical characteristics
| Average D-T neutron output per pulse, neutron/pulse |
1·1010 |
| Average D-D neutron output per pulse, neutron/pulse |
1·108 |
| Relative mean quadratic deviation of output from average, % |
35 |
| Neutron pulse duration at 0,5 amplitude value, nsec |
20 |
| Chamber operating life (number of turns-on) *, not less than |
1000 |
| Generator operating life (number of turns-on), not less than |
10000 |
| Operating temperature range |
-15 - +50 °C |
| Power supply |
220 V mains, 50 Hz |
| Power consumption, W |
100 |
| Weight, kg |
250 |
| Dimensions, mm |
600x400x1350 |
*) chamber is a replaceable part
Plasma focus chamber based pulsed neutron generator for physical research applications
The generator design includes:
- current pulse generator with plasma focus chamber;
- control unit;
- up to 50 m long connecting cables.
ING-104 technical characteristics
| Average D-T neutron output per pulse, neutron/pulse |
1·1011 |
| Average D-D neutron output per pulse, neutron/pulse |
1·109 |
| Relative mean quadratic deviation of output from average, % |
35 |
| Neutron pulse duration at 0,5 amplitude value, nsec |
30 |
| Chamber operating life (number of turns-on) *, not less than |
1000 |
| Generator operating life (number of turns-on), not less than |
10000 |
| Operating temperature range |
-15 - +50 °C |
| Power supply |
220 V mains, 50 Hz |
| Power consumption, W |
200 |
| Weight, kg |
500 |
| Dimensions, mm |
900x1100x1400 |
*) chamber is a replaceable part
|