Main:  X-ray units

  X-RAY UNITS  

One of the conversion trends of VNIIA activity is X-ray equipment development and production for industrial defectoscopy and security equipment.
In this field VNIIA is specialized in production of small sized X-ray generators with continuous anode voltage and up to 4 kW power. VNIIA develops and produces monoblock-type X-ray generators with mid-range conversion in the main circuit and adjustable stabilized continuous anode voltage.
Continuous voltage of anode is achieved by using diode-capacitive voltage-multiplying circuit.
VNIIA experience and technologies allow developing and producing all the parts and components of X-ray monoblocks including high-voltage transformers, capacitors and X-ray tubes.
 
X-ray tubes
X-ray tubes

Applications of VNIIA X-ray units:
- radiographic non-destructive testing in defectoscopy and industrial applications;
- luggage and posting examination;
- physical experiments and research.

Advantages of VNIIA X-ray units:
- high radiation penetration power;
- easy to operate;
- small weight and overall dimensions;
- low power consumption;
- wide operating range (temperature, humidity, mechanical load);
- high image quality;
- microprocessor control;
- equipment self-control.

RAPAN M 200/100            RAPAN 300/150            RAPAN 400/200            RAPAN 140/140

Download booklet in PDF
 
  RAPAN M 200/100 hand-held constant voltage X-ray equipment  

Applications: radiographic non-destructive testing and defectoscopy in industrial processes; luggage and posting examination; physical experiments and research.
Consists of X-ray unit, power supply unit, remote control, connection cable 15 m long.
 
 
RAPAN M 200/100
Technical characteristics:
X-ray equipment type
constant anode voltage, monoblock
X-ray tube anode voltage, kV
100-200
Voltage step adjustment
every 5 kV
Maximum power at X-ray tube anode, W
100
Radiation output
front, 120
Focal spot size, mm
Ø2.5
Maximum thickness of X-rayed steel (to film), mm, at a distance of 700 mm, exposure time 10 min, density 2:
- with 0.027 mm Pb screens ("Agfa Structurix" D7 film)
- with roentgen fluorescent screens (F8+RCF)


22
35
Operating conditions:
- ambient temperature, C
- humidity, %

from -40 to +40
up to 95
Maximum exposure time, min
15
Intensity of operation cycle
1:2
Power supply
mains 220 V, 50 Hz
Maximum power consumption, W
350
Dimensions, mm, not more:
- X-ray unit
- power supply unit
- remote control

Ø165 × 400
420 × 140 × 120
170 × 80 × 35
Weight, kg, not more:
- X-ray unit
- power supply unit
- remote control (including cable to power supply unit)
- cable, X-ray unit to power supply unit

10
3.5
2.5
4
Size-and-weight specifications in package, not more
single case: 20 kg,
420 × 400 × 200 mm

 
  RAPAN 300/150 hand-held constant voltage X-ray equipment  

Applications: radiographic non-destructive testing and defectoscopy in industrial processes; physical experiments and research.
Consists of X-ray unit, power supply unit, remote control, connection cable 15 m long.
 
 
RAPAN 300/150
Technical characteristics:
X-ray equipment type
constant anode voltage, monoblock
X-ray tube anode voltage, kV
200-300
Voltage step adjustment
every 10 kV
Maximum power at X-ray tube anode, W
150
Radiation output
side, 70 × 40
Focal spot size, mm
Ø1.5
Maximum thickness of X-rayed steel (to film), mm, at a distance of 700 mm, exposure time 10 min, density 2:
- with 0.027 mm Pb screens ("Agfa Structurix" D7 film)
- with roentgen fluorescent screens (F8+RCF)


36
64
Operating conditions:
- ambient temperature, C
- humidity, %

from -40 to +40
up to 95
Maximum exposure time, min
15
Time of continuous operation (maximum power, ambient temperature not more than +40C)
not limited
Power supply
mains 220 V, 50 Hz
Maximum power consumption, W
500
Dimensions, mm, not more:
- X-ray unit
- power supply unit
- remote control

Ø130 × 1200
420 × 140 × 120
170 × 80 × 35
Weight, kg, not more:
- X-ray unit
- power supply unit
- remote control (including cable to power supply unit)
- cable, X-ray unit to power supply unit

15
3.5
2.5
4
Size-and-weight specifications in package, not more
single case: 25 kg,
1250 × 350 × 250 mm

 
  RAPAN 400/200 hand-held constant voltage X-ray equipment
 

Applications: radiographic non-destructive testing and defectoscopy in industrial processes; physical experiments and research.
Consists of X-ray unit, power supply unit, remote control, connection cable 15 m long.
 
 
RAPAN 400/200
Technical characteristics:
X-ray equipment type
constant anode voltage, monoblock
X-ray tube anode voltage, kV
200-400
Voltage step adjustment
every 10 kV
Maximum power at X-ray tube anode, W
200
Radiation output
side, 70 × 40
Focal spot size, mm
Ø1.5
Maximum thickness of X-rayed steel (to film), mm, at a distance of 700 mm, exposure time 10 min, density 2:
- with 0.027 mm Pb screens ("Agfa Structurix" D7 film)
- with roentgen fluorescent screens (F8+RCF)


55
85
Operating conditions:
- ambient temperature, C
- humidity, %

from -40 to +40
up to 95
Maximum exposure time, min
15
Time of continuous operation (maximum power, ambient temperature not more than +40C)
not limited
Power supply
mains 220 V, 50 Hz
Maximum power consumption, W
500
Dimensions, mm, not more:
- X-ray unit
- power supply unit
- remote control

Ø145 × 950
420 × 140 × 120
170 × 80 × 35
Weight, kg, not more:
- X-ray unit
- power supply unit
- remote control (including cable to power supply unit)
- cable, X-ray unit to power supply unit

18
3.5
2.5
4
Size-and-weight specifications in package, not more, mm
two cases:
18 kg, 1000 × 350 × 250
10 kg, 420 × 400 × 200

 
  RAPAN 140/140 constant voltage X-ray generator
 

Designed for luggage and posting examination equipment.
Consists of X-ray unit, power supply and control unit, connection cable 3 m long.
 
 
RAPAN 140/140
Technical characteristics:
X-ray tube anode voltage (direct stabilized), kV
140, 150
Maximum power at X-ray tube anode, W
140
Focal spot size, mm
Ø0.8
Radiation output
side, 80 × 40
Radiation ripple, %
not more than 0.5
Power supply
mains 220 V, 50 Hz
Continuous running
23 hours per day
Dimensions, mm, not more:
- X-ray unit
- power supply and control unit

Ø120 × 660
420 × 140 × 120
Weight, kg, not more:
- X-ray unit
- power supply and control unit
- cable, X-ray unit to power supply and control unit

8.5
3.5
0.5

 
© FSUE "VNIIA", 2002-2015