Kinds of tests implemented at EMC Test Center
EMC standards applied to nuclear energy facilities pdf pdf, 9.955 Mb
EMC standards used for aircraft testing
Test methods | Parameters of test effects |
KT-160D Qualification Requirements. Operating conditions and environment for the on-board avionics. | |
Section 16.0. Power supply | |
Section 18.0. Susceptibility to audio frequency interference through power supply inputs | In the frequency range 700 Hz to 26 kHz with amplitude up to 4 V |
Section 19.0. Susceptibility to induction interference through communication wires and equipment housing | Magnetic and electric fields and pulses in connection cables |
Section 20.0. RF susceptibility (RF radiation and conductivity) | Effects range 10 kHz to 18 GHz, with possible loading up to 200 V/m with frequency and amplitude modulation |
Section 21.0. Emission of radiofrequency energy | Measurement range 0.15 MHz to 40 GHz in connection cables, in ambient space |
Section 22.0. Susceptibility to transients caused by lightning | Various types of tests: contact, single bolt, multiple bolts, multiple flash with different sets of waveforms |
Section 25.0. Susceptibility to electrostatic discharge | Amplitudes of effects up to 35 kV with various discharge tipsи |
GOST RV 6601-001-2008. On-board avionics. General requirements for sensitivity when exposed to electromagnetic interference, and measurement techniques | |
Section 5.1. Requirement of susceptibility to low frequency sinusoidal effects of conduction disturbances on power supply wires | Range of exposure 0 Hz to 150 kHz |
Section 5.2. Susceptibility requirement to high-frequency sinusoidal effects of conduction interference on communication lines and power supply wires | Range of exposure 10 kHz to 200 MHz |
Section 5.3. Requirement of susceptibility to pulsed effects on communication lines and power supply wires | Pulse repetition rate 30 Hz, duration 1 min |
Section 5.4. Requirement of susceptibility to pulsed effects of damped sinusoidal signal on communication lines, power supply and grounding wires | At frequencies 0.01 to 100 MHz |
Section 5.5. Requirement of susceptibility to electric field radiation in frequency range 2 MHz to 18 GHz on units and connection lines | At frequencies 2 to 18 GHz at load levels up to 200 V/m |
Capability to test for compliance with the MIL-STD-461F US standard
MIL-STD-461F Requirements for the control of electromagnetic interference characteristics of equipment subsystems US Department of Defense 10.12.2007: |
Emission Test procedures • CE101, conducted emissions, power leads, 30 Hz to 10 kHz • CE102, conducted emissions, power leads, 10 kHz to 2 MHz • RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz • RE102, radiated emissions, electric field, 2 MHz to 1 GHz |
Immunity
Limits and test procedures • CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz • CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz • CS115, Conducted susceptibility, bulk cable injection, 2 A impulse excitation |
• CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
• RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz • RS103, radiated susceptibility, electric field, 2 MHz to 18 GHz with 200 V/m amplitude |