Рус Eng

Kinds of tests implemented at EMC Test Center

EMC standards applied to nuclear energy facilities pdf pdf, 9.955 Mb

EMC standards used for aircraft testing

Test methods Parameters of test effects
KT-160D Qualification Requirements. Operating conditions and environment for the on-board avionics.  
Section 16.0. Power supply  
Section 18.0. Susceptibility to audio frequency interference through power supply inputs In the frequency range 700 Hz to 26 kHz with amplitude up to 4 V
Section 19.0. Susceptibility to induction interference through communication wires and equipment housing Magnetic and electric fields and pulses in connection cables
Section 20.0. RF susceptibility (RF radiation and conductivity) Effects range 10 kHz to 18 GHz, with possible loading up to 200 V/m with frequency and amplitude modulation
Section 21.0. Emission of radiofrequency energy Measurement range 0.15 MHz to 40 GHz in connection cables, in ambient space
Section 22.0. Susceptibility to transients caused by lightning Various types of tests: contact, single bolt, multiple bolts, multiple flash with different sets of waveforms
Section 25.0. Susceptibility to electrostatic discharge Amplitudes of effects up to 35 kV with various discharge tipsи
GOST RV 6601-001-2008. On-board avionics. General requirements for sensitivity when exposed to electromagnetic interference, and measurement techniques  
Section 5.1. Requirement of susceptibility to low frequency sinusoidal effects of conduction disturbances on power supply wires Range of exposure 0 Hz to 150 kHz
Section 5.2. Susceptibility requirement to high-frequency sinusoidal effects of conduction interference on communication lines and power supply wires Range of exposure 10 kHz to 200 MHz
Section 5.3. Requirement of susceptibility to pulsed effects on communication lines and power supply wires Pulse repetition rate 30 Hz, duration 1 min
Section 5.4. Requirement of susceptibility to pulsed effects of damped sinusoidal signal on communication lines, power supply and grounding wires At frequencies 0.01 to 100 MHz
Section 5.5. Requirement of susceptibility to electric field radiation in frequency range 2 MHz to 18 GHz on units and connection lines At frequencies 2 to 18 GHz at load levels up to 200 V/m

Capability to test for compliance with the MIL-STD-461F US standard

MIL-STD-461F
Requirements for the control of electromagnetic interference characteristics of equipment subsystems
US Department of Defense 10.12.2007:
Emission
Test procedures
• CE101, conducted emissions, power leads, 30 Hz to 10 kHz
• CE102, conducted emissions, power leads, 10 kHz to 2 MHz
• RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz
• RE102, radiated emissions, electric field, 2 MHz to 1 GHz
Immunity
Limits and test procedures
• CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz
• CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz
• CS115, Conducted susceptibility, bulk cable injection, 2 A impulse excitation
• CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
• RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz
• RS103, radiated susceptibility, electric field, 2 MHz to 18 GHz with 200 V/m amplitude

List of tested products

List of tested products and OKP codes pdf, 193 Kб

The accreditation scope of Test Center contains more than 250 items of technical equipment, covering almost all areas of the national economy.